Add to Cart
Top Quality Industry UPS Power Supply 100KVA 200KVA 300KVA 400KVA 500KVA 3 Phase UPS Long Backup Time From Factory Outlet
Performance Characteristics
*Advanced intelligent control technology for silicon - controlled rectifier and IGBT inverter control technology.
*Wide input voltage range with strong power grid adaptability.
*The output power factor is as high as 0.8.
*Can adapt to various generator equipment.
*The overall efficiency of the unit is as high as 90%, and the conversion efficiency in ECO mode is as high as 98%, with significant energy - saving effects.
*Strong load adaptability, as well as high output overload and short - circuit capabilities.
*The battery intelligent management system is designed to be adjustable on the operation panel, with 29 - 32 sections per group.
*Intelligent fault diagnosis, rich fault records, and large - capacity fault storage space.
*Using the latest digital signal controller (DSP) to achieve 100% digital control and operation of the system.
*Allows 100% three - phase unbalanced load.
*Supports SNMP network adapter, with standard RS232, USB, EPO, and remote emergency shutdown interfaces. RS485 and SNMP dry contacts are optional.
Scope of application
Industrial automation control, data center, communication base station, petrochemical, rail transit, medical and health, radio and television, military and national defense.
60KVA-200KVA power frequency UPS parameter table | |||||||
type | JHL/UPS3S - 60KS | JHL/UPS3S - 80KS | JHL/UPS3S - 100KS | JHL/UPS3S - 120KS | JHL/UPS3S - 160KS | JHL/UPS3S - 200KS | |
capacity | 60KVA/48KW | 80KVA/4KW | 100KVA/80KW | 120KVA/96KW | 160KVA/128KW | 200KVA/160KW | |
input power switch | nominal voltage | 3x380/400V (3Ph + N) | |||||
voltage range | 165V - 280V(phase voltage );285V - 485V(line voltage) | ||||||
frequency domain | 40Hz - 70Hz | ||||||
Rated current per phase | 108A | 130A | 160A | 200A | 277A | 330A | |
Battery Parameter | Lipo Cells | 29/30/31/32 knob(12V in series) | |||||
nominal voltage | 384VDC | ||||||
charge current | The default is 10A. Maximum: Capacity (KW)/total battery voltage (real-time voltage), maximum current does not exceed 40A | ||||||
floating charge voltage | 13.5VDC /x hours(12V) | ||||||
Over High Voltage Protection | 14.5VDC / x hours(12V) | ||||||
Inverter output | output waveform | Standard sine wave | |||||
nominal voltage | 3x380/400V (3Ph + N) | ||||||
error | ±1%(balanced load) | ||||||
rated frequency | 50/60Hz±1% | ||||||
voltage harmonic | Linear load < 2%; Nonlinear load < 5% | ||||||
overload capacity | 110% - 150% 10min = 60s;>160% 200ms | ||||||
efficiency | >90% | ||||||
Static switch bypass | nominal voltage | 3x380/400V (3Ph + N) | |||||
rated frequency | 50Hz/60Hz | ||||||
voltage range | 176V - 264V(phase voltage);304V - 456V(line voltage) | ||||||
frequency domain | 46Hz - 54Hz @50Hz;56Hz - 64Hz @60Hz | ||||||
transfer time | <10ms | ||||||
enviromental parameter | operating temperature range | 0°C - 55°C | |||||
humidity | 5%-95% no condensation | ||||||
IP class | IP20 | ||||||
type of cooling | forced air cooling | ||||||
structure parameter | communication mode | RS232,USB,RS485,intelligent slot | |||||
Machine size mm (width × depth × height) | 821×432×1159 | 975×554×1285 | 975×554×1285 | 975×635×1326 | 1051×705×1646 | 656×405×817 | |
Machine weight Kg | 365 | 471 | 537 | 650 | 760 | 256 |
60KVA-500KVA power frequency UPS parameter table | ||||||||
type | JHL/UPS3S - 60KS | JHL/UPS3S - 80KS | JHL/UPS3S - 100KS | JHL/UPS3S - 120KS | JHL/UPS3S - 160KS | JHL/UPS3S - 200KS | JHL/UPS3S - 500KS | |
capacity | 60KVA/48KW | 80KVA/4KW | 100KVA/80KW | 120KVA/96KW | 160KVA/128KW | 200KVA/160KW | 500KVA/400KW | |
input power switch | nominal voltage | 3x380/400V (3Ph + N) | ||||||
voltage range | 165V - 280V(phase voltage );285V - 485V(line voltage) | |||||||
frequency domain | 40Hz - 70Hz | |||||||
Rated current per phase | 108A | 130A | 160A | 200A | 277A | 330A | 890A | |
Battery Parameter | Lipo Cells | 29/30/31/32 knob(12V in series) | ||||||
nominal voltage | 384VDC | |||||||
charge current | The default is 10A. Maximum: Capacity (KW)/total battery voltage (real-time voltage), maximum current does not exceed 40A | |||||||
floating charge voltage | 13.5VDC /x hours(12V) | |||||||
Over High Voltage Protection | 14.5VDC / x hours(12V) | |||||||
Inverter output | output waveform | Standard sine wave | ||||||
nominal voltage | 3x380/400V (3Ph + N) | |||||||
error | ±1%(balanced load) | |||||||
rated frequency | 50/60Hz±1% | |||||||
voltage harmonic | Linear load < 2%; Nonlinear load < 5% | |||||||
overload capacity | 110% - 150% 10min = 60s;>160% 200ms | |||||||
efficiency | >90% | |||||||
Static switch bypass | nominal voltage | 3x380/400V (3Ph + N) | ||||||
rated frequency | 50Hz/60Hz | |||||||
voltage range | 176V - 264V(phase voltage);304V - 456V(line voltage) | |||||||
frequency domain | 46Hz - 54Hz @50Hz;56Hz - 64Hz @60Hz | |||||||
transfer time | <10ms | |||||||
enviromental parameter | operating temperature range | 0°C - 55°C | ||||||
humidity | 5%-95% no condensation | |||||||
IP class | IP20 | |||||||
type of cooling | forced air cooling | |||||||
structure parameter | communication mode | RS232,USB,RS485,intelligent slot | ||||||
Machine size mm (width × depth × height) | 821×432×1159 | 975×554×1285 | 975×554×1285 | 975×635×1326 | 1051×705×1646 | 656×405×817 | 1400*1000*1900 | |
Machine weight Kg | 365 | 471 | 537 | 650 | 760 | 256 | 2090 |
Sichuan Jinhuili Electric Co., Ltd. is specialized in distribution automation, power quality, energy efficiency management of the main products and services; The products include high and low voltage power distribution equipment, uninterruptible UPS power supply, emergency power supply, DC power supply, complete sets of intelligent control equipment, solar photovoltaic power generation, energy storage management, operation and maintenance and other comprehensive automation.
The company is located in Chengdu, Sichuan Province, China, covers an area of more than 10,000 square meters, has a large number of outstanding management personnel, senior engineers and power professional and technical personnel, has been awarded by the government and departments "civilized private enterprise", advanced private enterprise, scientific and technological innovation enterprise, contract-respecting, trustworthy units and other honorary titles.